The objective of this experiment is to,
The absorption capacity of brick sample 8 and 2 is 12.67% and 11.76% respectively. And the compressive strength of brick sample T and A is 23.54 MPa and 21.66 MPa respectively.
Brick samples 2 and 8 showed absorption capacities of 11.76% and 12.67%, respectively. These values indicate a moderate water absorption rate, suggesting that both bricks can absorb water without exceeding typical thresholds for construction-grade materials.
The results show that brick T exhibited a slightly higher compressive strength (23.54 MPa) than brick A (21.66 MPa). Both bricks fall within acceptable ranges for standard construction bricks, demonstrating their ability to bear significant structural loads. However, the difference in strength might be attributed to slight variations in material composition or manufacturing quality.